Correlation of crystal violet biofilm test results of Staphylococcus aureus clinical isolates with Raman spectroscopic read-out

dc.bibliographicCitation.firstPage2660eng
dc.bibliographicCitation.issue12eng
dc.bibliographicCitation.journalTitleJournal of Raman spectroscopy : JRSeng
dc.bibliographicCitation.lastPage2670eng
dc.bibliographicCitation.volume52eng
dc.contributor.authorEbert, Christina
dc.contributor.authorTuchscherr, Lorena
dc.contributor.authorUnger, Nancy
dc.contributor.authorPöllath, Christine
dc.contributor.authorGladigau, Frederike
dc.contributor.authorPopp, Jürgen
dc.contributor.authorLöffler, Bettina
dc.contributor.authorNeugebauer, Ute
dc.date.accessioned2022-03-24T06:38:36Z
dc.date.available2022-03-24T06:38:36Z
dc.date.issued2021
dc.description.abstractBiofilm-related infections occur quite frequently in hospital settings and require rapid diagnostic identification as they are recalcitrant to antibiotic therapy and make special treatment necessary. One of the standard microbiological in vitro tests is the crystal violet test. It indirectly determines the amount of biofilm by measuring the optical density (OD) of the crystal violet-stained biofilm matrix and cells. However, this test is quite time-consuming, as it requires bacterial cultivation up to several days. In this study, we correlate fast Raman spectroscopic read-out of clinical Staphylococcus aureus isolates from 47 patients with different disease background with their biofilm-forming characteristics. Included were low (OD < 10), medium (OD ≥ 10 and ≤20), and high (OD > 20) biofilm performers as determined by the crystal violet test. Raman spectroscopic analysis of the bacteria revealed most spectral differences between high and low biofilm performers in the fingerprint region between 750 and 1150 cm−1. Using partial least square regression (PLSR) analysis on the Raman spectra involving the three categories of biofilm formation, it was possible to obtain a slight linear correlation of the Raman spectra with the biofilm OD values. The PLSR loading coefficient highlighted spectral differences between high and low biofilm performers for Raman bands that represent nucleic acids, carbohydrates, and proteins. Our results point to a possible application of Raman spectroscopy as a fast prediction tool for biofilm formation of bacterial strains directly after isolation from the infected patient. This could help clinicians make timely and adapted therapeutic decision in future.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/8345
dc.identifier.urihttps://doi.org/10.34657/7383
dc.language.isoengeng
dc.publisherChichester [u.a.] : Wileyeng
dc.relation.doihttps://doi.org/10.1002/jrs.6237
dc.relation.essn1097-4555
dc.rights.licenseCC BY-NC 4.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/eng
dc.subject.ddc540eng
dc.subject.otherbiofilmeng
dc.subject.otherpartial least square regression (PLSR)eng
dc.subject.otherpatient isolateseng
dc.subject.otherRaman spectroscopyeng
dc.subject.otherStaphylococcus aureuseng
dc.titleCorrelation of crystal violet biofilm test results of Staphylococcus aureus clinical isolates with Raman spectroscopic read-outeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorIPHTeng
wgl.subjectChemieeng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Correlation_of_crystal_violet_biofilm.pdf
Size:
2.45 MB
Format:
Adobe Portable Document Format
Description:
Collections