3D analysis of low-voltage gas-filled DC switch using simplified arc model

Loading...
Thumbnail Image
Date
2019
Volume
6
Issue
1
Journal
Series Titel
Book Title
Publisher
Praha : Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Physics
Link to publishers version
Abstract

Electro-magnetic simulations have been used for the visualization of distribution of Lorentz force acting on a DC switching arc in low-voltage contactor. A simplified plasma model (black-box model) was applied for the description of arc conductivity. Arc geometry was gained from the high-speed camera images. Influence of arc position, arc current and of external magnetic field has been studied. Results have been compared with optical observations of the arc dynamics.

Description
Keywords
3D simulations, Arc dynamics, Black-box model, Lorentz force
Citation
Gortschakow, S., Gonzalez, D., Yu, S., & Werner, F. (2019). 3D analysis of low-voltage gas-filled DC switch using simplified arc model. 6(1). https://doi.org//10.14311/ppt.2019.1.65