Label-free CARS microscopy through a multimode fibre endoscope

dc.bibliographicCitation.firstPage30055eng
dc.bibliographicCitation.issue21eng
dc.bibliographicCitation.journalTitleOptics Expresseng
dc.bibliographicCitation.lastPage12eng
dc.bibliographicCitation.volume27eng
dc.contributor.authorTrägårdh, Johanna
dc.contributor.authorPikálek, Tomáš
dc.contributor.authorŠerý, Mojmír
dc.contributor.authorMeyer, Tobias
dc.contributor.authorPopp, Jürgen
dc.contributor.authorČižmár, Tomáš
dc.date.accessioned2020-01-03T14:03:29Z
dc.date.available2020-01-03T14:03:29Z
dc.date.issued2019
dc.description.abstractMultimode fibres have recently been employed as high-resolution ultra-thin endoscopes, capable of imaging biological structures deep inside tissue in vivo. Here, we extend this technique to label-free non-linear microscopy with chemical contrast using coherent anti-Stokes Raman scattering (CARS) through a multimode fibre endoscope, which opens up new avenues for instant and in-situ diagnosis of potentially malignant tissue. We use a commercial 125 µm diameter, 0.29 NA GRIN fibre, and wavefront shaping on an SLM is used to create foci that are scanned behind the fibre facet across the sample. The chemical selectivity is demonstrated by imaging 2 µm polystyrene and 2.5 µm PMMA beads with per pixel integration time as low as 1 ms for epi-detection.Multimode fibres have recently been employed as high-resolution ultra-thin endoscopes, capable of imaging biological structures deep inside tissue in vivo. Here, we extend this technique to label-free non-linear microscopy with chemical contrast using coherent anti-Stokes Raman scattering (CARS) through a multimode fibre endoscope, which opens up new avenues for instant and in-situ diagnosis of potentially malignant tissue. We use a commercial 125 µm diameter, 0.29 NA GRIN fibre, and wavefront shaping on an SLM is used to create foci that are scanned behind the fibre facet across the sample. The chemical selectivity is demonstrated by imaging 2 µm polystyrene and 2.5 µm PMMA beads with per pixel integration time as low as 1 ms for epi-detection.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://doi.org/10.34657/71
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/4800
dc.language.isoengeng
dc.publisherWashington D.C. : Optical Society of Americaeng
dc.relation.doihttps://doi.org/10.1364/OE.27.030055
dc.rights.licenseOSA Open Access Publishing Agreementeng
dc.rights.urihttps://www.osapublishing.org/library/license_v1.cfmeng
dc.subject.ddc620eng
dc.subject.othermultimode fibreeng
dc.subject.otherendoscopeeng
dc.subject.othermicroscopyeng
dc.titleLabel-free CARS microscopy through a multimode fibre endoscopeeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorIPHTeng
wgl.subjectIngenieurwissenschafteneng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Label-free CARS microscopy through a multimode fiber endoscope.pdf
Size:
3.59 MB
Format:
Adobe Portable Document Format
Description: