High-resolution diffusion kurtosis imaging at 3T enabled by advanced post-processing

dc.bibliographicCitation.firstPage427eng
dc.bibliographicCitation.journalTitleFrontiers in neuroscienceeng
dc.bibliographicCitation.volume8eng
dc.contributor.authorMohammadi, Siawoosh
dc.contributor.authorTabelow, Karsten
dc.contributor.authorRuthotto, Lars
dc.contributor.authorFeiweier, Thorsten
dc.contributor.authorPolzehl, Jörg
dc.contributor.authorWeiskopf, Nikolaus
dc.date.accessioned2022-07-21T12:12:15Z
dc.date.available2022-07-21T12:12:15Z
dc.date.issued2015
dc.description.abstractDiffusion Kurtosis Imaging (DKI) is more sensitive to microstructural differences and can be related to more specific micro-scale metrics (e.g., intra-axonal volume fraction) than diffusion tensor imaging (DTI), offering exceptional potential for clinical diagnosis and research into the white and gray matter. Currently DKI is acquired only at low spatial resolution (2–3 mm isotropic), because of the lower signal-to-noise ratio (SNR) and higher artifact level associated with the technically more demanding DKI. Higher spatial resolution of about 1 mm is required for the characterization of fine white matter pathways or cortical microstructure. We used restricted-field-of-view (rFoV) imaging in combination with advanced post-processing methods to enable unprecedented high-quality, high-resolution DKI (1.2 mm isotropic) on a clinical 3T scanner. Post-processing was advanced by developing a novel method for Retrospective Eddy current and Motion ArtifacT Correction in High-resolution, multi-shell diffusion data (REMATCH). Furthermore, we applied a powerful edge preserving denoising method, denoted as multi-shell orientation-position-adaptive smoothing (msPOAS). We demonstrated the feasibility of high-quality, high-resolution DKI and its potential for delineating highly myelinated fiber pathways in the motor cortex. REMATCH performs robustly even at the low SNR level of high-resolution DKI, where standard EC and motion correction failed (i.e., produced incorrectly aligned images) and thus biased the diffusion model fit. We showed that the combination of REMATCH and msPOAS increased the contrast between gray and white matter in mean kurtosis (MK) maps by about 35% and at the same time preserves the original distribution of MK values, whereas standard Gaussian smoothing strongly biases the distribution.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/9767
dc.identifier.urihttps://doi.org/10.34657/8805
dc.language.isoengeng
dc.publisherLausanne : Frontiers Research Foundationeng
dc.relation.doihttps://doi.org/10.3389/fnins.2014.00427
dc.relation.essn1662-453X
dc.rights.licenseCC BY 4.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/eng
dc.subject.ddc610eng
dc.subject.otherAdaptive smoothingeng
dc.subject.otherDiffusion kurtosiseng
dc.subject.otherDKIeng
dc.subject.otherDTIeng
dc.subject.otherEddy current and motion artifactseng
dc.subject.otherGray mattereng
dc.subject.otherHigh-resolutioneng
dc.subject.otherMulti-shell dMRIeng
dc.titleHigh-resolution diffusion kurtosis imaging at 3T enabled by advanced post-processingeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorWIASeng
wgl.subjectMedizin, Gesundheiteng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
High-resolution_diffusion.pdf
Size:
5.92 MB
Format:
Adobe Portable Document Format
Description:
Collections