Towards shot-noise limited diffraction experiments with table-top femtosecond hard x-ray sources

dc.bibliographicCitation.firstPage054304
dc.bibliographicCitation.issue5
dc.bibliographicCitation.volume4
dc.contributor.authorHoltz, Marcel
dc.contributor.authorHauf, Christoph
dc.contributor.authorWeisshaupt, Jannick
dc.contributor.authorSalvador, Antonio-Andres Hernandez
dc.contributor.authorWoerner, Michael
dc.contributor.authorElsaesser, Thomas
dc.date.accessioned2023-06-05T08:24:24Z
dc.date.available2023-06-05T08:24:24Z
dc.date.issued2017
dc.description.abstractTable-top laser-driven hard x-ray sources with kilohertz repetition rates are an attractive alternative to large-scale accelerator-based systems and have found widespread applications in x-ray studies of ultrafast structural dynamics. Hard x-ray pulses of 100 fs duration have been generated at the Cu Kα wavelength with a photon flux of up to 109 photons per pulse into the full solid angle, perfectly synchronized to the sub- 100-fs optical pulses from the driving laser system. Based on spontaneous x-ray emission, such sources display a particular noise behavior which impacts the sensitivity of x-ray diffraction experiments. We present a detailed analysis of the photon statistics and temporal fluctuations of the x-ray flux, together with experimental strategies to optimize the sensitivity of optical pump/x-ray probe experiments. We demonstrate measurements close to the shot-noise limit of the x-ray source.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/12404
dc.identifier.urihttp://dx.doi.org/10.34657/11436
dc.language.isoeng
dc.publisherMelville, NY : AIP Publishing LLC
dc.relation.doihttps://doi.org/10.1063/1.4991355
dc.relation.essn2329-7778
dc.relation.ispartofseriesStructural Dynamics 4 (2017), Nr. 5eng
dc.rights.licenseCC BY 4.0 Unported
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectElectron sourceseng
dc.subjectLaser pulseseng
dc.subjectOptical pumpingeng
dc.subjectPhotonseng
dc.subjectStructural dynamicseng
dc.subjectX-ray apparatuseng
dc.subjectX-rayseng
dc.subject.ddc530
dc.subject.ddc500
dc.titleTowards shot-noise limited diffraction experiments with table-top femtosecond hard x-ray sourceseng
dc.typearticle
dc.typeText
dcterms.bibliographicCitation.journalTitleStructural Dynamics
tib.accessRightsopenAccess
wgl.contributorMBI
wgl.subjectPhysikger
wgl.typeZeitschriftenartikelger