Search Results

Now showing 1 - 10 of 20
  • Item
    Sperm Micromotors for Cargo Delivery through Flowing Blood
    (Washington, DC : American Chemical Society, 2020) Xu, Haifeng; Medina-Sánchez, Mariana; Maitz, Manfred F.; Werner, Carsten; Schmidt, Oliver G.
    Micromotors are recognized as promising candidates for untethered micromanipulation and targeted cargo delivery in complex biological environments. However, their feasibility in the circulatory system has been limited due to the low thrust force exhibited by many of the reported synthetic micromotors, which is not sufficient to overcome the high flow and complex composition of blood. Here we present a hybrid sperm micromotor that can actively swim against flowing blood (continuous and pulsatile) and perform the function of heparin cargo delivery. In this biohybrid system, the sperm flagellum provides a high propulsion force while the synthetic microstructure serves for magnetic guidance and cargo transport. Moreover, single sperm micromotors can assemble into a train-like carrier after magnetization, allowing the transport of multiple sperm or medical cargoes to the area of interest, serving as potential anticoagulant agents to treat blood clots or other diseases in the circulatory system.
  • Item
    A Rotating Spiral Micromotor for Noninvasive Zygote Transfer
    (Hoboke, NJ : Wiley, 2020) Schwarz, Lukas; Karnaushenko, Dmitriy D.; Hebenstreit, Franziska; Naumann, Ronald; Schmidt, Oliver G.; Medina-Sánchez, Mariana
    Embryo transfer (ET) is a decisive step in the in vitro fertilization process. In most cases, the embryo is transferred to the uterus after several days of in vitro culture. Although studies have identified the beneficial effects of ET on proper embryo development in the earlier stages, this strategy is compromised by the necessity to transfer early embryos (zygotes) back to the fallopian tube instead of the uterus, which requires a more invasive, laparoscopic procedure, termed zygote intrafallopian transfer (ZIFT). Magnetic micromotors offer the possibility to mitigate such surgical interventions, as they have the potential to transport and deliver cellular cargo such as zygotes through the uterus and fallopian tube noninvasively, actuated by an externally applied rotating magnetic field. This study presents the capture, transport, and release of bovine and murine zygotes using two types of magnetic micropropellers, helix and spiral. Although helices represent an established micromotor architecture, spirals surpass them in terms of motion performance and with their ability to reliably capture and secure the cargo during both motion and transfer between different environments. Herein, this is demonstrated with murine oocytes/zygotes as the cargo; this is the first step toward the application of noninvasive, magnetic micromotor‐assisted ZIFT.
  • Item
    Stamping Fabrication of Flexible Planar Micro‐Supercapacitors Using Porous Graphene Inks
    (Hoboken : Wiley, 2020) Li, Fei; Qu, Jiang; Li, Yang; Wang, Jinhui; Zhu, Minshen; Liu, Lixiang; Ge, Jin; Duan, Shengkai; Li, Tianming; Bandari, Vineeth Kumar; Huang, Ming; Zhu, Feng; Schmidt, Oliver G.
    High performance, flexibility, safety, and robust integration for micro‐supercapacitors (MSCs) are of immense interest for the urgent demand for miniaturized, smart energy‐storage devices. However, repetitive photolithography processes in the fabrication of on‐chip electronic components including various photoresists, masks, and toxic etchants are often not well‐suited for industrial production. Here, a cost‐effective stamping strategy is developed for scalable and rapid preparation of graphene‐based planar MSCs. Combining stamps with desired shapes and highly conductive graphene inks, flexible MSCs with controlled structures are prepared on arbitrary substrates without any metal current collectors, additives, and polymer binders. The interdigitated MSC exhibits high areal capacitance up to 21.7 mF cm−2 at a current of 0.5 mA and a high power density of 6 mW cm−2 at an energy density of 5 µWh cm−2. Moreover, the MSCs show outstanding cycling performance and remarkable flexibility over 10 000 charge–discharge cycles and 300 bending cycles. In addition, the capacitance and output voltage of the MSCs are easily adjustable through interconnection with well‐defined arrangements. The efficient, rapid manufacturing of the graphene‐based interdigital MSCs with outstanding flexibility, shape diversity, and high areal capacitance shows great potential in wearable and portable electronics.
  • Item
    Selective Out‐of‐Plane Optical Coupling between Vertical and Planar Microrings in a 3D Configuration
    (Hoboken, NJ : Wiley, 2020) Valligatla, Sreeramulu; Wang, Jiawei; Madani, Abbas; Naz, Ehsan Saei Ghareh; Hao, Qi; Saggau, Christian Niclaas; Yin, Yin; Ma, Libo; Schmidt, Oliver G.
    3D photonic integrated circuits are expected to play a key role in future optoelectronics with efficient signal transfer between photonic layers. Here, the optical coupling of tubular microcavities, supporting resonances in a vertical plane, with planar microrings, accommodating in‐plane resonances, is explored. In such a 3D coupled composite system with largely mismatched cavity sizes, periodic mode splitting and resonant mode shifts are observed due to mode‐selective interactions. The axial direction of the microtube cavity provides additional design freedom for selective mode coupling, which is achieved by carefully adjusting the axial displacement between the microtube and the microring. The spectral anticrossing behavior is caused by strong coupling in this composite optical system and is excellently reproduced by numerical modeling. Interfacing tubular microcavities with planar microrings is a promising approach toward interlayer light transfer with added optical functionality in 3D photonic systems.
  • Item
    Towards Bacteria Counting in DI Water of Several Microliters or Growing Suspension Using Impedance Biochips
    (Basel : MDPI, 2020) Kiani, Mahdi; Tannert, Astrid; Du, Nan; Hübner, Uwe; Skorupa, Ilona; Bürger, Danilo; Zhao, Xianyue; Blaschke, Daniel; Rebohle, Lars; Cherkouk, Charaf; Neugebauer, Ute; Schmidt, Oliver G.; Schmidt, Heidemarie
    We counted bacterial cells of E. coli strain K12 in several-microliter DI water or in several-microliter PBS in the low optical density (OD) range (OD = 0.05–1.08) in contact with the surface of Si-based impedance biochips with ring electrodes by impedance measurements. The multiparameter fit of the impedance data allowed calibration of the impedance data with the concentration cb of the E. coli cells in the range of cb = 0.06 to 1.26 × 109 cells/mL. The results showed that for E. coli in DI water and in PBS, the modelled impedance parameters depend linearly on the concentration of cells in the range of cb = 0.06 to 1.26 × 109 cells/mL, whereas the OD, which was independently measured with a spectrophotometer, was only linearly dependent on the concentration of the E. coli cells in the range of cb = 0.06 to 0.50 × 109 cells/mL.
  • Item
    Highly Symmetric and Extremely Compact Multiple Winding Microtubes by a Dry Rolling Mechanism
    (Weinheim : Wiley-VCH, 2020) Moradi, Somayeh; Naz, Ehsan Saei Ghareh; Li, Guodong; Bandari, Nooshin; Bandari, Vineeth Kumar; Zhu, Feng; Wendrock, Horst; Schmidt, Oliver G.
    Rolled-up nanotechnology has received significant attention to self-assemble planar nanomembranes into 3D micro and nanotubular architectures. These tubular structures have been well recognized as novel building blocks in a variety of applications ranging from microelectronics and nanophotonics to microbatteries and microrobotics. However, fabrication of multiwinding microtubes with precise control over the winding interfaces, which is crucial for many complex applications, is not easy to achieve by existing materials and technologies. Here, a dry rolling approach is introduced to tackle this challenge and create tight windings in compact and highly symmetric cylindrical microstructures. This technique exploits hydrophobicity of fluorocarbon polymers and the thermal expansion mismatch of polymers and inorganic films upon thermal treatment. Quality parameters for rolled-up microtubes, against which different fabrication technologies can be benchmarked are defined. The technique offers to fabricate long freestanding multiwinding microtubes as well as hierarchical architectures incorporating rolled-up wrinkled nanomembranes. This work presents an important step forward toward the fabrication of more complex but well-controlled microtubes for advanced high-quality device architectures. © 2020 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
  • Item
    Antifreezing Hydrogel with High Zinc Reversibility for Flexible and Durable Aqueous Batteries by Cooperative Hydrated Cations
    (Weinheim : Wiley-VCH, 2020) Zhu, Minshen; Wang, Xiaojie; Tang, Hongmei; Wang, Jiawei; Hao, Qi; Liu, Lixiang; Li, Yang; Zhang, Kai; Schmidt, Oliver G.
    Hydrogels are widely used in flexible aqueous batteries due to their liquid-like ion transportation abilities and solid-like mechanical properties. Their potential applications in flexible and wearable electronics introduce a fundamental challenge: how to lower the freezing point of hydrogels to preserve these merits without sacrificing hydrogels' basic advantages in low cost and high safety. Moreover, zinc as an ideal anode in aqueous batteries suffers from low reversibility because of the formation of insulative byproducts, which is mainly caused by hydrogen evolution via extensive hydration of zinc ions. This, in principle, requires the suppression of hydration, which induces an undesirable increase in the freezing point of hydrogels. Here, it is demonstrated that cooperatively hydrated cations, zinc and lithium ions in hydrogels, are very effective in addressing the above challenges. This simple but unique hydrogel not only enables a 98% capacity retention upon cooling down to −20 °C from room temperature but also allows a near 100% capacity retention with >99.5% Coulombic efficiency over 500 cycles at −20 °C. In addition, the strengthened mechanical properties of the hydrogel under subzero temperatures result in excellent durability under various harsh deformations after the freezing process. © 2019 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
  • Item
    Human spermbots for patient-representative 3D ovarian cancer cell treatment
    (Cambridge : RSC Publ., 2020) Xu, Haifeng; Medina-Sánchez, Mariana; Zhang, Wunan; Seaton, Melanie P. H.; Brison, Daniel R.; Edmondson, Richard J.; Taylor, Stephen S.; Nelson, Louisa; Zeng, Kang; Bagley, Steven; Ribeiro, Carla; Restrepo, Lina P.; Lucena, Elkin; Schmidt, Christine K.; Schmidt, Oliver G.
    Cellular micromotors are attractive for locally delivering high concentrations of drug, and targeting hard-to-reach disease sites such as cervical cancer and early ovarian cancer lesions by non-invasive means. Spermatozoa are highly efficient micromotors perfectly adapted to traveling up the female reproductive system. Indeed, bovine sperm-based micromotors have shown potential to carry drugs toward gynecological cancers. However, due to major differences in the molecular make-up of bovine and human sperm, a key translational bottleneck for bringing this technology closer to the clinic is to transfer this concept to human material. Here, we successfully load human sperm with Doxorubicin (DOX) and perform treatment of 3D cervical cancer and patient-representative ovarian cancer cell cultures, resulting in strong anticancer cell effects. Additionally, we define the subcellular localization of the chemotherapeutic drug within human sperm, using high-resolution optical microscopy. We also assess drug effects on sperm motility and viability over time, employing sperm samples from healthy donors as well as assisted reproduction patients. Finally, we demonstrate guidance and release of human drug-loaded sperm onto cancer tissues using magnetic microcaps, and show the sperm microcap loaded with a second anticancer drug, camptothecin (CPT), which unlike DOX is not suitable for directly loading into sperm due to its hydrophobic nature. This co-drug delivery approach opens up novel targeted combinatorial drug therapies for future applications. © 2020 The Royal Society of Chemistry.
  • Item
    Steering Directional Light Emission and Mode Chirality through Postshaping of Cavity Geometry
    (Hoboke, NJ : Wiley, 2020) Wang, Jiawei; Tang, Min; Yang, Yue-De; Yin, Yin; Chen, Yan; Saggau, Christian Niclaas; Zhu, Minshen; Yuan, Xiaobo; Karnaushenko, Dmitriy; Huang, Yong-Zhen; Ma, Libo; Schmidt, Oliver G.
    Dielectric optical microcavities have been explored as an excellent platform to manipulate the light flow and investigate non‐Hermitian physics in open optical systems. For whispering gallery mode optical microcavities, modifying the rotational symmetry is highly desirable for intriguing phenomena such as degenerated chiral modes and directional light emission. However, for the state‐of‐the‐art approaches, namely deforming the cavity geometry by precision lithography or introducing local scatterers near the cavity boundary via micromanipulation, there is a lack of flexibility in fine‐adjusting of chiral symmetry and far‐field emission direction. Here, precise engineering of cavity boundary using electron‐beam‐induced deposition is reported based on rolled‐up nanomembrane‐enabled spiral‐shaped microcavities. The deformation of outer boundary results in delicate tailoring of asymmetric backscattering between the outer and inner rolling edges, and hence deterministically strong mode chirality. Besides, the crescent‐shaped high‐index nanocap leads to modified light tunneling channels and inflected far‐field emission angle. It is envisioned that such a localized deposition‐assisted technique for adjusting the structural deformation of 3D optical microcavities will be highly useful for understanding rich insights in non‐Hermitian photonics and unfolding exotic properties on lasing, sensing, and cavity quantum electrodynamics.
  • Item
    Integrated molecular diode as 10 MHz half-wave rectifier based on an organic nanostructure heterojunction
    ([London] : Nature Publishing Group UK, 2020) Li, Tianming; Bandari, Vineeth Kumar; Hantusch, Martin; Xin, Jianhui; Kuhrt, Robert; Ravishankar, Rachappa; Xu, Longqian; Zhang, Jidong; Knupfer, Martin; Zhu, Feng; Yan, Donghang; Schmidt, Oliver G.
    Considerable efforts have been made to realize nanoscale diodes based on single molecules or molecular ensembles for implementing the concept of molecular electronics. However, so far, functional molecular diodes have only been demonstrated in the very low alternating current frequency regime, which is partially due to their extremely low conductance and the poor degree of device integration. Here, we report about fully integrated rectifiers with microtubular soft-contacts, which are based on a molecularly thin organic heterojunction and are able to convert alternating current with a frequency of up to 10 MHz. The unidirectional current behavior of our devices originates mainly from the intrinsically different surfaces of the bottom planar and top microtubular Au electrodes while the excellent high frequency response benefits from the charge accumulation in the phthalocyanine molecular heterojunction, which not only improves the charge injection but also increases the carrier density.