Search Results

Now showing 1 - 3 of 3
  • Item
    Performance analysis of an optically pumped magnetometer in Earth’s magnetic field
    (London : SpringerOpen, 2019) Oelsner, Gregor; Schultze, Volkmar; Ijsselsteijn, Rob; Stolz, Ronny
    We experimentally investigate the influence of the orientation of optically pumped magnetometers in Earth’s magnetic field. We focus our analysis to an operational mode that promises femtotesla field resolutions at such field strengths. For this so-called light-shift dispersed Mz (LSD-Mz) regime, we focus on the key parameters defining its performance. That are the reconstructed Larmor frequency, the transfer function between output signal and magnetic field amplitude as well as the shot noise limited field resolution. We demonstrate that due to the use of two well balanced laser beams for optical pumping with different helicities the heading error as well as the field sensitivity of a detector both are only weakly influenced by the heading in a large orientation angle range.
  • Item
    OPM magnetorelaxometry in the presence of a DC bias field
    (Berlin ; Heidelberg [u.a.] : Springer Open, 2020) Jaufenthaler, Aaron; Schultze, Volkmar; Scholtes, Theo; Schmidt, Christian B.; Handler, Michael; Stolz, Ronny; Baumgarten, Daniel
    Spatial quantitative information about magnetic nanoparticle (MNP) distributions is a prerequisite for biomedical applications like magnetic hyperthermia and magnetic drug targeting. This information can be gathered by means of magnetorelaxometry (MRX) imaging, where the relaxation of previously aligned MNP’s magnetic moments is measured by sensitive magnetometers and an inverse problem is solved. To remove or minimize the magnetic shielding in which MRX imaging is carried out today, the knowledge of the influence of background magnetic fields on the MNP’s relaxation is a prerequisite. We show MRX measurements using an intensity-modulated optically pumped magnetometer (OPM) in background magnetic fields of up to 100μT. We show that the relaxation parameters alter or may be intentionally altered significantly by applying static fields parallel or antiparallel to the MNP’s alignment direction. Further, not only the relaxation process of the MNP’s magnetic moments could be measured with OPM, but also their alignment due to the MRX excitation field. © 2020, The Author(s).
  • Item
    An optically pumped magnetometer working in the light-shift dispersed Mz mode
    (Basel : MDPI, 2017) Schultze, Volkmar; Schillig, Bastian; IJsselsteijn, Rob; Scholtes, Theo; Woetzel, Stefan; Stolz, Ronny
    We present an optically pumped magnetometer working in a new operational mode—the light-shift dispersed Mz (LSD-Mz) mode. It is realized combining various features; (1) high power off-resonant optical pumping; (2) Mz configuration, where pumping light and magnetic field of interest are oriented parallel to each other; (3) use of small alkali metal vapor cells of identical properties in integrated array structures, where two such cells are pumped by circularly polarized light of opposite helicity; and (4) subtraction of the Mz signals of these two cells. The LSD-Mz magnetometer’s performance depends on the inherent and very complex interplay of input parameters. In order to find the configuration of optimal magnetometer resolution, a sensitivity analysis of the input parameters by means of Latin Hypercube Sampling was carried out. The resulting datasets of the multi-dimensional parameter space exploration were assessed by a subsequent physically reasonable interpretation. Finally, the best shot-noise limited magnetic field resolution was determined within that parameter space. As the result, using two 50 mm3 integrated vapor cells a magnetic field resolution below 10 fT/√Hz at Earth’s magnetic field strength is possible