Search Results

Now showing 1 - 10 of 210
  • Item
    Mechanical Robustness of Graphene on Flexible Transparent Substrates
    (Washington, DC : Soc., 2016) Kang, Moon H.; Prieto López, Lizbeth O.; Chen, Bingan; Teo, Ken; Williams, John A.; Milne, William I.; Cole, Matthew T.
    This study reports on a facile and widely applicable method of transferring chemical vapor deposited (CVD) graphene uniformly onto optically transparent and mechanically flexible substrates using commercially available, low-cost ultraviolet adhesive (UVA) and hot-press lamination (HPL). We report on the adhesion potential between the graphene and the substrate, and we compare these findings with those of the more commonly used cast polymer handler transfer processes. Graphene transferred with the two proposed methods showed lower surface energy and displayed a higher degree of adhesion (UVA: 4.40 ± 1.09 N/m, HPL: 0.60 ± 0.26 N/m) compared to equivalent CVD-graphene transferred using conventional poly(methyl methacrylate) (PMMA: 0.44 ± 0.06 N/m). The mechanical robustness of the transferred graphene was investigated by measuring the differential resistance as a function of bend angle and repeated bend–relax cycles across a range of bend radii. At a bend angle of 100° and a 2.5 mm bend radius, for both transfer techniques, the normalized resistance of graphene transferred on polyethylene terephthalate (PET) was around 80 times less than that of indium–tin oxide on PET. After 104 bend cycles, the resistance of the transferred graphene on PET using UVA and HPL was found to be, on average, around 25.5 and 8.1% higher than that of PMMA-transferred graphene, indicating that UVA- and HPL-transferred graphene are more strongly adhered compared to PMMA-transferred graphene. The robustness, in terms of maintained electrical performance upon mechanical fatigue, of the transferred graphene was around 60 times improved over ITO/PET upon many thousands of repeated bending stress cycles. On the basis of present production methods, the development of the next-generation of highly conformal, diverse form factor electronics, exploiting the emerging family of two-dimensional materials, necessitates the development of simple, low-cost, and mechanically robust transfer processes; the developed UVA and HPL approaches show significant potential and allow for large-area-compatible, near-room temperature transfer of graphene onto a diverse range of polymeric supports.
  • Item
    Formation mechanism for stable hybrid clusters of proteins and nanoparticles
    (Washington D.C. : American Chemical Society, 2015) Moerz, Sebastian T.; Kraegeloh, Annette; Chanana, Munish; Kraus, Tobias
    Citrate-stabilized gold nanoparticles (AuNP) agglomerate in the presence of hemoglobin (Hb) at acidic pH. The extent of agglomeration strongly depends on the concentration ratio [Hb]/[AuNP]. Negligible agglomeration occurs at very low and very high [Hb]/[AuNP]. Full agglomeration and precipitation occur at [Hb]/[AuNP] corresponding to an Hb monolayer on the AuNP. Ratios above and below this value lead to the formation of an unexpected phase: stable, microscopic AuNP–Hb agglomerates. We investigated the kinetics of agglomeration with dynamic light scattering and the adsorption kinetics of Hb on planar gold with surface-acoustic wave-phase measurements. Comparing agglomeration and adsorption kinetics leads to an explanation of the complex behavior of this nanoparticle–protein mixture. Agglomeration is initiated either when Hb bridges AuNP or when the electrostatic repulsion between AuNP is neutralized by Hb. It is terminated when Hb has been depleted or when Hb forms multilayers on the agglomerates that stabilize microscopic clusters indefinitely.
  • Item
    Surviving the surf: The tribomechanical properties of the periostracum of Mytilus sp
    (Amsterdam : Elsevier, 2014) Wählisch, Felix C.; Peter, Nicolas J.; Torrents Abad, Oscar; Oliveira, Mariana V.G.; Schneider, Andreas S.; Schmahl, Wolfgang; Griesshaber, Erika; Bennewitz, Roland
    We investigated the friction and wear behavior as well as the mechanical properties of the periostracum of Mytilus sp. Tribological properties were determined with a reciprocal sliding microtribometer, while mechanical characterization was performed using a nanoindenter. Measurements were performed in dry and wet conditions. On the dry periostracum we found a low friction coefficient of 0.078 ± 0.007 on the young parts and a higher one of 0.63 ± 0.02 on the old parts of the shell. Under wet, saline, conditions we only observed one average coefficient of friction of 0.37 ± 0.01. Microscopic ex situ analysis indicated that dry periostracum wore rather rapidly by plowing and fatigue, while it exhibited a high wear resistance when immersed in salt water. The Young’s modulus and hardness of the periostracum were also investigated in both dry and wet conditions. Under dry conditions the Young’s modulus of the periostracum was 8 ± 3 GPa, while under wet conditions it was 0.21 ± 0.05 GPa. The hardness of dry periostracum samples was 353 ± 127 MPa, whereas the hardness of wet samples was 5 ± 2 MPa. It was found that, in the wet state, viscous behavior plays a significant role in the mechanical response of the periostracum. Our results strongly indicate that the periostracum can provide an important contribution to the overall wear resistance of Mytilus sp. shell.
  • Item
    Analysis of fatty acids and triacylglycerides by Pd nanoparticle-assisted laser desorption/ionization mass spectrometry
    (Cambridge : Royal Society of Chemistry, 2015) Silina, Yuliya E.; Fink-Straube, Claudia; Hayen, Heiko; Volmer, Dietrich A.
    In this study, we propose a simple and rapid technique for characterization of free fatty acids and triacylglycerides (TAG) based on palladium nanoparticular (Pd-NP) surface-assisted laser desorption/ionization (SALDI) mass spectrometry (MS). The implemented Pd-NP material allowed detection of free fatty acids and TAGs exclusively as [M + K]+ ions in positive ion mode. Under negative ionization conditions, unusual trimetric structures were generated for free fatty acids, while TAGs underwent irreproducible degradation reactions. Importantly, the mass spectra obtained from Pd-NP targets in positive ion mode were very clean without interferences from matrix-derived ions in the low m/z range and readily enabled the detection of intact TAGs in vegetable oils without major fragmentation reactions as compared to conventional MALDI-MS, requiring only a minimal amount of sample preparation.
  • Item
    Tris(tetrahydrofuran-kO)tris[tris(thio-phen-2-yl)methanolato-kO]terbium(III)tetrahydrofuran monosolvate
    (Chester : International Union of Crystallography, 2011) Veith, Michael; Belot, Celine; Huch, Volker
    In the mononuclear title compound, [Tb(C13H9OS3)3(C4H8O)3]·C4H8O, the lanthanide cation is located on a threefold rotation axis and is surrounded by electron-rich ligands in an approximately octahedral geometry. One of the thienyl groups and the bound THF are disordered with 0.5:0.5 occupancy. The free THF is disordered around the threefold axis.
  • Item
    Real-time monitoring of calcium carbonate and cationic peptide deposition on carboxylate-SAM using a microfluidic SAW biosensor
    (Frankfurt am Main : Beilstein-Institut, 2014) Pohl, Anna; Weiss, Ingrid M.
    A microfluidic biosensor with surface acoustic wave technology was used in this study to monitor the interaction of calcium carbonate with standard carboxylate self-assembled monolayer sensor chips. Different fluids, with and without biomolecular components, were investigated. The pH-dependent surface interactions of two bio-inspired cationic peptides, AS8 and ES9, which are similar to an extracellular domain of the chitin synthase involved in mollusc shell formation, were also investigated in a biological buffer system. A range of experimental conditions are described that are suitable to study non-covalent molecular interactions in the presence of ionic substances, such as, mineral precursors below the solubility equilibrium. The peptide ES9, equal to the mollusc chitin synthase epitope, is less sensitive to changes in pH than its counterpart AS8 with a penta-lysine core, which lacks the flanking acidic residues. This study demonstrates the extraordinary potential of microfluidic surface acoustic wave biosensors to significantly expand our experimental capabilities for studying the principles underlying biomineralization in vitro.
  • Item
    Quantitative multichannel NC-AFM data analysis of graphene growth on SiC(0001)
    (Frankfurt am Main : Beilstein-Institut, 2012) Held, Christian; Seyller, Thomas; Bennewitz, Roland
    Noncontact atomic force microscopy provides access to several complementary signals, such as topography, damping, and contact potential. The traditional presentation of such data sets in adjacent figures or in colour-coded pseudo-three-dimensional plots gives only a qualitative impression. We introduce two-dimensional histograms for the representation of multichannel NC-AFM data sets in a quantitative fashion. Presentation and analysis are exemplified for topography and contact-potential data for graphene grown epitaxially on 6H-SiC(0001), as recorded by Kelvin probe force microscopy in ultrahigh vacuum. Sample preparations by thermal decomposition in ultrahigh vacuum and in an argon atmosphere are compared and the respective growth mechanisms discussed.
  • Item
    Switchable Adhesion Surfaces with Enhanced Performance Against Rough Counterfaces
    (Basel : MDPI, 2016) Prieto-López, Lizbeth; Williams, John
    In a recent study, we demonstrated that the pressurization of micro-fluidic features introduced in the subsurface of a soft polymer can be used to actively modify the magnitude of the adhesion to a harder counterface by changing its waviness or long wavelength undulations. In that case, both contacting surfaces had very smooth finishes with root-mean-square roughnesses of less than 20 nm. These values are far from those of many engineering surfaces, which usually have a naturally occurring roughness of between ten and a hundred times this value. In this work, we demonstrate that appropriate surface features, specifically relatively slender “fibrils”, can enhance the ability of a such a soft surface to adhere to a hard, but macroscopically rough, counterface, while still maintaining the possibility of switching the adhesion force from one level to another. Conversely, stiffer more conical surface features can suppress adhesion even against a smooth counterface. Examples of each form of topography can be found in the natural world.
  • Item
    Quantification of internalized silica nanoparticles via STED microscopy
    (London : Hindawi, 2015) Peuschel, Henrike; Ruckelshausen, Thomas; Cavelius, Christian; Kraegeloh, Annette
    The development of safe engineered nanoparticles (NPs) requires a detailed understanding of their interaction mechanisms on a cellular level. Therefore, quantification of NP internalization is crucial to predict the potential impact of intracellular NP doses, providing essential information for risk assessment as well as for drug delivery applications. In this study, the internalization of 25 nm and 85 nm silica nanoparticles (SNPs) in alveolar type II cells (A549) was quantified by application of super-resolution STED (stimulated emission depletion) microscopy. Cells were exposed to equal particle number concentrations (9.2 x 10^10 particles mL^-1) of each particle size and the sedimentation of particles during exposure was taken into account. Microscopy images revealed that particles of both sizes entered the cells after 5 h incubation in serum supplemented and serum-free medium. According to the in vitro sedimentation, diffusion, and dosimetry (ISDD) model 20–27 of the particles sedimented. In comparison, 102-103 NPs per cell were detected intracellularly serum-containing medium. Furthermore, in the presence of serum, no cytotoxicity was induced by the SNPs. In serum-free medium, large agglomerates of both particle sizes covered the cells whereas only high concentrations (≥ 3.8 × 10^12 particles mL^-1) of the smaller particles induced cytotoxicity.
  • Item
    In situ measurements with CPC micro-actuators using SEM
    (Bellingham : SPIE, 2014) Kaasik, Friedrich; Must, Indrek; Lust, Enn; Jürgens, Meelis; Presser, Volker; Punning, Andres; Temmer, Rauno; Kiefer, Rudolf; Aabloo, Alvo
    Comparative measurements of carbon-polymer composite micro-actuators based on room temperature ionic liquid electrolyte were carried out in situ (1) in vacuum using a state-of-the-art scanning electron microscope, (2) in an oxygen-free atmosphere under ambient pressure, and (3) under ambient environment. The fabricated micro-actuators sustained their actuation performance in all three environments, revealing important implications regarding their humidity-dependence. SEM observations demonstrate high stroke actuation of a device with submillimeter length, which is the typical size range of actuators desirable for medical or lab-on-chip applications.