Search Results

Now showing 1 - 2 of 2
  • Item
    Super-resolution RESOLFT microscopy of lipid bilayers using a fluorophore-switch dyad
    (Cambridge : RSC, 2020) Frawley, Andrew T.; Wycisk, Virginia; Xiong, Yaoyao; Galiani, Silvia; Sezgin, Erdinc; Urbančič, Iztok; Vargas Jentzsch, Andreas; Leslie, Kathryn G.; Eggeling, Christian; Anderson, Harry L.
    Dyads consisting of a photochromic switch covalently linked to a fluorescent dye allow the emission from the dye to be controlled by reversible photoisomerization of the switch; one form of the switch quenches fluorescence by accepting energy from the dye. Here we investigate the use of dyads of this type for super-resolution imaging of lipid bilayers. Giant unilamellar vesicles stained with the dyads were imaged with about a two-fold resolution-enhancement compared with conventional confocal microscopy. This was achieved by exciting the fluorophore at 594 nm, using a switch activated by violet and red light (405/640 nm). This journal is © The Royal Society of Chemistry.
  • Item
    Vibrational sum-frequency generation spectroscopy of lipid bilayers at repetition rates up to 100 kHz
    (Melville, NY : American Institute of Physics, 2018) Yesudas, Freeda; Mero, Mark; Kneipp, Janina; Heiner, Zsuzsanna
    Broadband vibrational sum-frequency generation (BB-VSFG) spectroscopy has become a well-established surface analytical tool capable of identifying the orientation and structure of molecular layers. A straightforward way to boost the sensitivity of the technique could be to increase the laser repetition rate beyond that of standard BB-VSFG spectrometers, which rely on Ti:sapphire lasers operating at repetition rates of 1-5 kHz. Nevertheless, possible thermally induced artifacts in the vibrational spectra due to higher laser average powers are unexplored. Here, we discuss laser power induced temperature accumulation effects that distort the BB-VSFG spectra of 1,2-diacyl-sn-glycero-3-phosphocholine at an interface between two transparent phases at repetition rates of 5, 10, 50, and 100 kHz at constant pulse energy. No heat-induced distortions were found in the spectra, suggesting that the increase in the laser repetition rate provides a feasible route to an improved signal-to-noise ratio or shorter data acquisition times in BB-VSFG spectroscopy for thin films on transparent substrates. The results have implications for future BB-VSFG spectrometers pushing the detection limit for molecular layers with low surface coverage.