Absorption instruments inter-comparison campaign at the Arctic Pallas station

Abstract

Aerosol light absorption was measured during a 1-month field campaign in June-July 2019 at the Pallas Global Atmospheric Watch (GAW) station in northern Finland. Very low aerosol concentrations prevailed during the campaign, which posed a challenge for the instruments' detection capabilities. The campaign provided a real-world test for different absorption measurement techniques supporting the goals of the European Metrology Programme for Innovation and Research (EMPIR) Black Carbon (BC) project in developing aerosol absorption standard and reference methods. In this study we compare the results from five filter-based absorption techniques - aethalometer models AE31 and AE33, a particle soot absorption photometer (PSAP), a multi-angle absorption photometer (MAAP), and a continuous soot monitoring system (COSMOS) - and from one indirect technique called extinction minus scattering (EMS). The ability of the filter-based techniques was shown to be adequate to measure aerosol light absorption coefficients down to around 0.01g¯Mm-1 levels when data were averaged to 1-2g¯h. The hourly averaged atmospheric absorption measured by the reference MAAP was 0.09g¯Mm-1 (at a wavelength of 637g¯nm). When data were averaged for >1g¯h, the filter-based methods agreed to around 40g¯%. COSMOS systematically measured the lowest absorption coefficient values, which was expected due to the sample pre-treatment in the COSMOS inlet. PSAP showed the best linear correlation with MAAP (slopeCombining double low line0.95, R2Combining double low line0.78), followed by AE31 (slopeCombining double low line0.93). A scattering correction applied to PSAP data improved the data accuracy despite the added noise. However, at very high scattering values the correction led to an underestimation of the absorption. The AE31 data had the highest noise and the correlation with MAAP was the lowest (R2Combining double low line0.65). Statistically the best linear correlations with MAAP were obtained for AE33 and COSMOS (R2 close to 1), but the biases at around the zero values led to slopes clearly below 1. The sample pre-treatment in the COSMOS instrument resulted in the lowest fitted slope. In contrast to the filter-based techniques, the indirect EMS method was not adequate to measure the low absorption values found at the Pallas site. The lowest absorption at which the EMS signal could be distinguished from the noise was >0.1g¯Mm-1 at 1-2g¯h averaging times. The mass absorption cross section (MAC) value measured at a range 0-0.3g¯Mm-1 was calculated using the MAAP and a single particle soot photometer (SP2), resulting in a MAC value of 16.0±5.7g¯m2g-1. Overall, our results demonstrate the challenges encountered in the aerosol absorption measurements in pristine environments and provide some useful guidelines for instrument selection and measurement practices. We highlight the need for a calibrated transfer standard for better inter-comparability of the absorption results. © Author(s) 2021.

Description
Keywords
absorption coefficient, aerosol, concentration (composition), COSMOS, cross section, detection method, instrumentation, monitoring system, wavelength, Arctic, Finland, Lappi [Finland], Pallas
Citation
Asmi, E., Backman, J., Servomaa, H., Virkkula, A., Gini, M. I., Eleftheriadis, K., et al. (2021). Absorption instruments inter-comparison campaign at the Arctic Pallas station. 14(8). https://doi.org//10.5194/amt-14-5397-2021
License
CC BY 4.0 Unported