The use of matrix-specific calibrations for oxygen in analytical glow discharge spectrometry
dc.bibliographicCitation.firstPage | 7473 | eng |
dc.bibliographicCitation.issue | 29 | eng |
dc.bibliographicCitation.journalTitle | Analytical and Bioanalytical Chemistry | eng |
dc.bibliographicCitation.volume | 406 | eng |
dc.contributor.author | Gonzalez-Gago, C. | |
dc.contributor.author | Smid, P. | |
dc.contributor.author | Hofmann, T. | |
dc.contributor.author | Venzago, C. | |
dc.contributor.author | Hoffmann, V. | |
dc.contributor.author | Gruner, W. | |
dc.date.accessioned | 2020-09-06T07:58:41Z | |
dc.date.available | 2020-09-06T07:58:41Z | |
dc.date.issued | 2014 | |
dc.description.abstract | The performance of glow discharge optical emission spectroscopy and mass spectrometry for oxygen determination is investigated using a set of new conductive samples containing oxygen in the percent range in three different matrices (Al, Mg, and Cu) prepared by a sintering process. The sputtering rate corrected calibrations obtained at standard conditions for the 4 mm anode (700 V, 20 mA) in GD-OES are matrix independent for Mg and Al but not for Cu. The importance of a "blue shifted" line of oxygen at 130.22 nm (first reported by Köster) for quantitative analyses by GD-OES is confirmed. Matrix-specific calibrations for oxygen in GD-MS are presented. Two source concepts - fast flow (ELEMENT GD) and low gas flow (VG9000) - are evaluated obtaining higher sensitivity with the static flow source. Additional experiments using Ar-He mixtures or μs pulsed GD are carried out in ELEMENT GD aiming to improve the oxygen sensitivity. | eng |
dc.description.version | publishedVersion | eng |
dc.identifier.uri | https://doi.org/10.34657/4214 | |
dc.identifier.uri | https://oa.tib.eu/renate/handle/123456789/5585 | |
dc.language.iso | eng | eng |
dc.publisher | Dordrecht : Springer | eng |
dc.relation.doi | https://doi.org/10.1007/s00216-014-8186-9 | |
dc.relation.issn | 1618-2642 | |
dc.rights.license | CC BY 4.0 Unported | eng |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | eng |
dc.subject.ddc | 540 | eng |
dc.subject.other | GD-MS | eng |
dc.subject.other | GD-OES | eng |
dc.subject.other | Glow discharge analysis | eng |
dc.subject.other | Oxygen determination | eng |
dc.subject.other | Aluminum | eng |
dc.subject.other | Calibration | eng |
dc.subject.other | Emission spectroscopy | eng |
dc.subject.other | Flow of gases | eng |
dc.subject.other | Glow discharges | eng |
dc.subject.other | Mass spectrometry | eng |
dc.subject.other | Optical emission spectroscopy | eng |
dc.subject.other | Sintering | eng |
dc.subject.other | Additional experiments | eng |
dc.subject.other | Discharge analysis | eng |
dc.subject.other | Glow discharge spectrometries | eng |
dc.subject.other | Glow-discharge optical emission spectroscopy | eng |
dc.subject.other | Oxygen determination | eng |
dc.subject.other | Oxygen sensitivity | eng |
dc.subject.other | Sintering process | eng |
dc.subject.other | Standard conditions | eng |
dc.subject.other | Oxygen | eng |
dc.title | The use of matrix-specific calibrations for oxygen in analytical glow discharge spectrometry | eng |
dc.type | Article | eng |
dc.type | Text | eng |
tib.accessRights | openAccess | eng |
wgl.contributor | IFWD | eng |
wgl.subject | Chemie | eng |
wgl.type | Zeitschriftenartikel | eng |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Gonzalez-Gago2014.pdf
- Size:
- 687.11 KB
- Format:
- Adobe Portable Document Format
- Description: