The use of matrix-specific calibrations for oxygen in analytical glow discharge spectrometry

dc.bibliographicCitation.firstPage7473eng
dc.bibliographicCitation.issue29eng
dc.bibliographicCitation.journalTitleAnalytical and Bioanalytical Chemistryeng
dc.bibliographicCitation.volume406eng
dc.contributor.authorGonzalez-Gago, C.
dc.contributor.authorSmid, P.
dc.contributor.authorHofmann, T.
dc.contributor.authorVenzago, C.
dc.contributor.authorHoffmann, V.
dc.contributor.authorGruner, W.
dc.date.accessioned2020-09-06T07:58:41Z
dc.date.available2020-09-06T07:58:41Z
dc.date.issued2014
dc.description.abstractThe performance of glow discharge optical emission spectroscopy and mass spectrometry for oxygen determination is investigated using a set of new conductive samples containing oxygen in the percent range in three different matrices (Al, Mg, and Cu) prepared by a sintering process. The sputtering rate corrected calibrations obtained at standard conditions for the 4 mm anode (700 V, 20 mA) in GD-OES are matrix independent for Mg and Al but not for Cu. The importance of a "blue shifted" line of oxygen at 130.22 nm (first reported by Köster) for quantitative analyses by GD-OES is confirmed. Matrix-specific calibrations for oxygen in GD-MS are presented. Two source concepts - fast flow (ELEMENT GD) and low gas flow (VG9000) - are evaluated obtaining higher sensitivity with the static flow source. Additional experiments using Ar-He mixtures or μs pulsed GD are carried out in ELEMENT GD aiming to improve the oxygen sensitivity.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://doi.org/10.34657/4214
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/5585
dc.language.isoengeng
dc.publisherDordrecht : Springereng
dc.relation.doihttps://doi.org/10.1007/s00216-014-8186-9
dc.relation.issn1618-2642
dc.rights.licenseCC BY 4.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/eng
dc.subject.ddc540eng
dc.subject.otherGD-MSeng
dc.subject.otherGD-OESeng
dc.subject.otherGlow discharge analysiseng
dc.subject.otherOxygen determinationeng
dc.subject.otherAluminumeng
dc.subject.otherCalibrationeng
dc.subject.otherEmission spectroscopyeng
dc.subject.otherFlow of gaseseng
dc.subject.otherGlow dischargeseng
dc.subject.otherMass spectrometryeng
dc.subject.otherOptical emission spectroscopyeng
dc.subject.otherSinteringeng
dc.subject.otherAdditional experimentseng
dc.subject.otherDischarge analysiseng
dc.subject.otherGlow discharge spectrometrieseng
dc.subject.otherGlow-discharge optical emission spectroscopyeng
dc.subject.otherOxygen determinationeng
dc.subject.otherOxygen sensitivityeng
dc.subject.otherSintering processeng
dc.subject.otherStandard conditionseng
dc.subject.otherOxygeneng
dc.titleThe use of matrix-specific calibrations for oxygen in analytical glow discharge spectrometryeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorIFWDeng
wgl.subjectChemieeng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gonzalez-Gago2014.pdf
Size:
687.11 KB
Format:
Adobe Portable Document Format
Description:
Collections