Sensor for oxygen activity measurements in glass melts

Loading...
Thumbnail Image
Date
1991
Volume
64
Issue
Journal
Series Titel
Book Title
Publisher
Offenbach : Verlag der Deutschen Glastechnischen Gesellschaft
Link to publishers version
Abstract

Traditional oxygen activity measurement in glass melts is based on Y2O3-stabilized ZrO2 which, in continuous use in the glassworks, is subjected to considerable wear. The present paper describes an oxygen sensor that is not equipped with wear parts. The new sensor is far less sensitive to temperature gradients in the surrounding area than ZrO2 sensors; the oxygen measurement, however, is greatly disturbed at direct flame irradiation.

Description
Keywords
Citation
Müller-Simon, H., & Mergler, K. W. (1991). Sensor for oxygen activity measurements in glass melts. 64.
License
CC BY 3.0 DE