Sensor for oxygen activity measurements in glass melts

Loading...
Thumbnail Image

Date

Volume

64

Issue

Journal

Glastechnische Berichte

Series Titel

Book Title

Publisher

Offenbach : Verlag der Deutschen Glastechnischen Gesellschaft

Link to publishers version

Abstract

Traditional oxygen activity measurement in glass melts is based on Y2O3-stabilized ZrO2 which, in continuous use in the glassworks, is subjected to considerable wear. The present paper describes an oxygen sensor that is not equipped with wear parts. The new sensor is far less sensitive to temperature gradients in the surrounding area than ZrO2 sensors; the oxygen measurement, however, is greatly disturbed at direct flame irradiation.

Description

Keywords

License

CC BY 3.0 DE