Quantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry

Abstract

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 () was found between 3D and 2D quantification of BIC. The μCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.

Description
Keywords
Algorithms, Alloys, Animals, Coated Materials, Biocompatible, Ethylenediamines, Female, Imaging, Three-Dimensional, Materials Testing, Osseointegration, Polyamines, Prostheses and Implants, Rats, Rats, Sprague-Dawley, Tibia, Titanium, X-Ray Microtomography, allylamine, ethylenediamine, biocompatible coated material, ethylenediamine derivative, polyallylamine, titanium alloy (TiAl6V4), animal experiment, animal model, bone implant, bone implant contact, bone regeneration, bone strength, comparative study, controlled study, correlation coefficient, image quality, image reconstruction, metal implant, micro-computed tomography, morphometrics, musculoskeletal system parameters, nonhuman, micro-computed tomography, pathology, prostheses and orthoses;surgery
Citation
Gabler, C., Zietz, C., Bieck, R., Göhler, R., Lindner, T., Haenle, M., et al. (2015). Quantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry. 2015. https://doi.org//10.1155/2015/103137
License
CC BY 3.0 Unported